The Flowserve N65 leakage collection and detection system is designed for general industry and is used with single mechanical seals on process fluids that condense at ambient atmospheric conditions. Mechanical seal failure can be detected when an excessive flow rate into the system increases the fluid level in the reservoir.
... Read more Read less- Maximum absolute working pressure (MAWP) 27.6 bar at 149°C (400 psi at 300°F)
- Ambidextrous mounting options for easy installation
- Designed with standard 3 liter (0.79 US gallon) effective volume
- All stainless-steel construction for superior corrosion protection
- Low-cost and easy-to-install standard NPT connections and construction
- Pre-configured switch selections for reduced lead-time
- Designed in accordance with ASME VIII.1 with optional U-stamp
- Optional PED and CRN compliance
Standards
- ASME BPVC Section VIII Div. 1
- Pressure Equipment Directive (PED) 2014/68/EU
- CSA B51
Operating Parameters
- MAWP: 400 psi @300F (27.6 bar @ 149C)
- MDMT: -49F (-45C) Min. operating temp: -0F(-17C)
Varies by instrumentation rating
Size Range: Effective Volume - 0.79 U.S. Gallon (3.0 Liter)
Materials: All 316 stainless-steel construction
- Plan 65A or B
Connections
- NPT